Voltmeter Loading: a 1 MΩ Meter on a 1 MΩ + 1 MΩ Divider
A 10 V battery feeds a 1 MΩ + 1 MΩ divider. The inline voltmeter has a 1 MΩ input, so across the lower half it reads 3.33 V instead of 5 V: meter loading.
Learn to use a multimeter, with circuits you can measure
Want to build your own circuit? Start a new circuit in the circuit simulator
Teaching with circuits?
Create a classroom, give your students a circuit to build, and review what they submit. Try it free with one classroom and up to 5 students.
Try the free classroom demoHow it works
A 10 V battery feeds two 1 MΩ resistors in series. Without a meter, the middle point sits at 5 V. The inline voltmeter across the lower resistor has a 1 MΩ input, so in parallel with that resistor it makes 500 kΩ, and the divider becomes 1 MΩ over 500 kΩ: 10 V × 500 kΩ / 1.5 MΩ = 3.33 V. The meter reads 3.33 V.
This is voltmeter loading: a meter changes the circuit it measures when its input resistance is not far above the circuit's. The lab's digital multimeter reads as an ideal meter and does not load the circuit.
What's inside
- 1× Battery
- 2× Resistor (1 MΩ)
- Measured with Voltmeter/Ammeter